Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 478
Filtrar
1.
Front Dent ; 21: 6, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38571895

RESUMO

Objectives: Durable bonding to zirconia is a challenging issue in dentistry. This study aimed to assess the effect of bioglass coating of zirconia on the microshear bond strength of resin cement to zirconia and to study the effect of thermocycling on this bond. Materials and Methods: This in-vitro experimental study was conducted on 60 yttria-stabilized tetragonal zirconia blocks in six groups (N=10) based on surface pretreatment and thermocycling. Surface pretreatments included no treatment control, alumina particle abrasion, and bioglass-coating of zirconia. Resin bonding was performed with Panavia F2.0 cements. Then, half of the specimens underwent a 24-hour incubation in 37°C water, while the other half were subjected to thermocycling (12000 cycles, 5-55°C, 60s for each batch) following the same incubation period. Subsequently, the microshear bond strength of the specimens was measured. Additionally, one block from each group was subjected to scanning electron microscopy and X-ray diffraction. The data were analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: There was a significant difference between the bond strength values of different groups (P<0.001). Alumina particle abrasion and bioglass coating equally increased the bond strength compared to the untreated control group (P<0.001). Thermocycling caused significant decreases in bond strength in all the groups (P<0.001); however, the bond strength value of the thermocycled bioglass-coated group was significantly higher than that reported for the thermocycled alumina particle abraded group (P=0.015). Conclusion: Despite the decrease in the bond strength values after thermocycling, the long-term efficacy of the bioglass coating of zirconia was promising.

2.
Cureus ; 16(3): e55911, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38601407

RESUMO

Background Attachments play a vital role in aligner-led orthodontic therapy, first passively through retention of the appliance and secondly, through bringing about tooth movement, by virtue of its active surfaces, to achieve treatment goals. Additionally, irregularities on the surface of attachments attract plaque adhesion. Thus the effect of brushing with different toothbrushes on the surface of attachments is an important factor to study. This would allow clinicians to better advise patients who are undergoing aligner therapy. Four types of brushes are available commercially, namely hard, medium, soft, and ultra-soft. This study analyses the interaction between the kind of toothbrush used and the wear of the surface of the aligner attachment, to understand the impact of a toothbrush on the attachment. Aim To observe the surface wear and change in the shape of the aligner attachment on brushing with four varying hardness of toothbrush bristle (ultra-soft, soft, medium, and hard) over six months to three years. Material and methods One attachment was bonded to the buccal surface of extracted premolars. One tooth with attachment was subjected to SEM analysis and the rest were divided into four groups of five teeth each, based on the type of toothbrush to be used. Brushing with hard, medium, soft, and ultra-soft toothbrushes was carried out in a brushing simulator in two cycles simulating six months, one year, 18 months, and three years of brushing. A contact profilometer was used to evaluate surface roughness before and after brushing and pre- and post-surface roughness values were compared to quantitate changes after which SEM analysis was carried out for qualitative assessment of the surface of the samples. The Shapiro-Wilks test was applied to evaluate the normality of the data, followed by the one-way ANOVA, and statistical significance was applied at p<0.05. Results At six months, the samples brushed with the medium toothbrush showed the least surface roughness (0.2±0.192) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (1.9±0.159). At one year, the samples brushed with the soft toothbrush showed the least surface roughness (0.46 ±0.31) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (2.12 ±0.12). At the 1.5-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.43±0.39) and the highest in the soft toothbrush group (1.6± 0.41). At the three-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.28 ± 0.17) and the highest in the medium toothbrush group (1.6 ± 0.31). Conclusion Ultra-soft toothbrushes have a high abrasive potential, as seen by higher surface roughness values over six months and one year. Morphometric changes were the most noticeable for attachments brushed by hard-bristled toothbrushes and medium-bristled brushes.

3.
Cureus ; 16(2): e55009, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38550459

RESUMO

Aim The aim of this study was to evaluate the shear bond strength between dual cure and light cure resin cements in root surface indirect restorations. Materials and methods Ten recently extracted human teeth were selected. Cylindrical blocks of resin were prepared and bonded near the Cemento-Enamel Junction (CEJ) of the prepared teeth to mimic the restoration at the root surface. The samples were randomly luted to the root surface using the light cure (Calibra Veneer, Dentsply Sirona, India) and dual cure (Fusion Ultra D/C, DenPro, USA) forming two groups. The bond strength was checked using the INSTRON 3000 device (INSTRON, MA, USA). The point of fracture of the prepared sample from the tooth surface was noted. All readings were tabulated and further statistically analyzed. Results On comparing the two groups, it was found that the light cured resin had a greater mean shear bond strength (57 N) than the dual cure resin cement (41 N). The difference in the mean value of the shear bond strength between two resin cements was found to be statistically not significant according to independent T-test analysis using Levene's Test (P>0.05). Conclusion From the results obtained and within the limits of the study conducted, we can infer that Calibra Veneer is a more viable option for luting to the root surface area. On the other hand, Fusion Ultra Dual cure resin cement seems to have similar results but has a lower bond strength than the other.

4.
Polymers (Basel) ; 16(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38475265

RESUMO

The degree of monomer conversion and polymerization shrinkage are two of the main reasons for potential adhesion failure between the tooth structure and the restoration substrate. To evaluate the degree of conversion and polymerization shrinkage of a newly developed self-adhesive resin cement, the degree of conversion (DC) was measured using FTIR under different activation modes, temperatures, and times. Volumetric shrinkage was tested using the AcuVol video imaging method. The experimental cement showed a higher DC than other cements under self-curing. The DC of the experimental cement was higher than that of other cements, except SpeedCem Plus under light curing. The experimental cement had a higher DC than other cements, except SpeedCem Plus in some conditions under dual curing. All self-adhesive cements had a higher DC at 37 °C than at 23 °C under self-curing, and there was no statistical difference between 23 °C and 37 °C under light curing. All self-adhesive cements showed a significantly higher DC at 10 min than at 5 min under self-curing. There was no statistical difference between 5 min and 10 min for most cements under dual curing. All self-adhesive cements statistically had the same volumetric shrinkage under light curing and self-curing. The newly developed self-adhesive resin cement exhibited a higher degree of conversion and similar volumetric shrinkage compared to these commercial self-adhesive resin cements.

5.
Dent Res J (Isfahan) ; 21: 19, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476715

RESUMO

Background: This study assessed the effect of different concentrations of 4-methacryloyloxyethy trimellitate anhydride (4-META) added to silane on microtensile bond strength (µTBS) of light-cure and dual-cure resin cement to hybrid and zirconia-reinforced lithium silicate ceramics. Materials and Methods: This in vitro, experimental study was conducted on 32 Celtra Duo and 32 VITA Enamic ceramics bonded to Allcem Veneer light-cure and Allcem dual-cure resin cements using silane impregnated with 4-META in 0%, 2.5%, 5%, and 10 wt% concentrations in 16 groups (n = 4). The µTBS of specimens was measured by a universal testing machine and analyzed by the Kruskal-Wallis and Mann-Whitney tests, and the mode of failure was determined under a stereomicroscope and analyzed by the Chi-square test (alpha = 0.05). Results: The lowest mean µTBS was recorded in the Enamic ceramic group with 4-META (0%) bonded to dual-cure cement (14.26 MPa), and the highest mean µTBS was recorded in Enamic ceramic with 4-META (10%) bonded to light-cure cement (18.59 MPa) (P < 0.001). The µTBS of Celtra Duo was significantly higher than that of Enamic in bonding to light-cure cement using 4-META (2.5%) (P = 0.003). All failures (100%) were adhesive in most groups. The frequency of adhesive failure was the lowest (90%) in Celtra Duo bonded to dual-cure cement with 4-META (5%). Conclusion: According to the results of this pilot study, the addition of 4-META (10%) to silane caused a significant improvement in µTBS to light-cure cement. The addition of 4-META in all concentrations significantly improved the µTBS to Enamic ceramic in the use of dual-cure cement; however, it had no significant effect on µTBS of Celtra Duo. Nonetheless, the results should be interpreted with caution due to the relatively small sample size.

6.
J Adhes Dent ; 26(1): 79-86, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465402

RESUMO

PURPOSE: This investigation aimed to assess the impact of additive manufacturing-generated surface textures on zirconia bond strength. MATERIALS AND METHODS: Zirconia samples (n = 144) fabricated using digital light-processing (DLP) technology were categorized into 6 groups according to the type of surface conditioning (group NN: no designs, no air abrasion; group NY: no designs, with air abrasion; group GN: groove designs, no air abrasion; group GY: groove designs with air abrasion; group HN: hexagon grid, no air abrasion; group HY: hexagon grid, with air abrasion). Composite resin cylinders were cemented to the treated zirconia surfaces with dual-curing, self-adhesive resin cement (Clearfil SA Luting). The shear bond strength (SBS) was tested after water storage for 3 days or 3 days with an additional 10,000 thermocycles. RESULTS: The zirconia samples fabricated using DLP technology have high accuracy. The SBS of the NY, GY, and HY groups did not significantly differ after 3 days, and neither did the SBS of the NN, GN, and HN groups. The NN, NY, and HY groups exhibited reduced SBS compared to their initial values following artificial aging, while the SBS of the remaining three groups were not diminished. The GY group obtained the highest SBS value after aging. CONCLUSION: Printing grooves with air abrasion can improve the bond strength.


Assuntos
Colagem Dentária , Abrasão Dental por Ar , Propriedades de Superfície , Cimentos de Resina/química , Resinas Compostas , Resistência ao Cisalhamento , Zircônio/química , Teste de Materiais , Análise do Estresse Dentário
7.
Saudi Dent J ; 36(2): 234-239, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420009

RESUMO

The field of dentistry is constantly evolving and increasingly embracing minimally invasive approaches. One such approach, which is bonding to the tooth structure, particularly enamel, has been shown to offer the most predictable outcomes. However, there are instances where significant tooth loss may limit treatment options for a restorative dentist. In these scenarios, indirect restoration might be the preferred treatment option. This literature review provides a comprehensive examination of the currently available resin luting agents and their bonding requirements. It provides valuable insights for dental professionals seeking an in-depth understanding of the current state of the field and the future prospects of dental adhesion.

8.
J Mech Behav Biomed Mater ; 151: 106353, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38194785

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of the thickness of resin-matrix composite blocks manufactured by CAD-CAM on the light transmittance towards different resin-matrix cements or flowable composites. METHODS: Sixty specimens of resin-matrix composite CAD-CAM blocks reinforced with 89 wt% inorganic fillers were cross-sectioned with 2 or 3 mm thicknesses. The specimens were conditioned with adhesive system and divided in groups according to the luting material, namely: two dual-cured resin-matrix cements, two traditional flowable resin-matrix composites, and one thermal-induced flowable resin-matrix composite. Specimens were light-cured at 900 mW/cm2 for 40s. Light transmittance assays were preformed using a spectrophotometer with an integrated monochromator before and after light-curing. Microstructural analysis was performed by optical and scanning electron microscopy (SEM). Nanoindentation tests were performed to evaluate mechanical properties for indirect evaluation of degree of monomers conversion. RESULTS: Optical and SEM images revealed low thickness values for the cementation interfaces for the traditional flowable resin-matrix composite. The cement thickness increased with the size and content of inorganic fillers. The highest light transmittance was recorded for the onlay blocks cemented with the traditional flowable resin-matrix composites while a group cemented with the dual-cured resin-matrix cement revealed the lowest light transmittance. The elastic modulus and hardness increased for specimens with high content of inorganic fillers as well as it increased in function of the light transmittance. CONCLUSIONS: The light transmittance of flowable resin-matrix composites was higher than that for resin-matrix cement after cementation to resin-matrix composites blocks. The type, size, and content of inorganic fillers of the luting material affected the thickness of the cement layer and light transmittance through the materials. CLINICAL RELEVANCE: On chair-side light curing, the transmission of visible light can be interfered by the chemical composition and viscosity of the luting materials. The increase in size and content of inorganic fillers of resin-matrix composites and luting materials can decrease the light transmittance leading to inefficient polymerization.


Assuntos
Resinas Compostas , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Propriedades de Superfície , Cura Luminosa de Adesivos Dentários/métodos , Resinas Compostas/química , Cimentos de Resina/química
9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1003441

RESUMO

Objective@#To investigate the clinical effect of lithium disilicate glass ceramic cantilever resin-bonded fixed partial dentures (CRBFPDs) on single anterior tooth loss to provide a reference for the selection of restoration methods for single anterior tooth loss.@*Methods@#This study was reviewed and approved by the Ethics Committee, and informed consent was obtained from the patients. Forty-two patients with less than two anterior teeth with monomaxillary loss were included in this study. After 6 months, 1 year, 2 years, and 3 years, the aesthetic and functional effects of the restorations and the periodontal health status were evaluated, and the visual analog scale (VAS) was used to assess patient satisfaction.@*Results@#During the observation period, the connector fractured in one case within 3 months. One case had debonded within 2 years. The aesthetic restoration effect of all lithium disilicate glass ceramic CRBFPDs was categorized as Class A. The periodontal health was good, there was no clinical absorption in the soft and hard tissues of the abutment or subbridge, periodontal status according to the evaluation indices was classified as class A, and the total satisfaction rate of the patient was 100%.@*Conclusion@#For single anterior tooth loss patients, lithium disilicate glass ceramic cantilever resin-bonded fixed partial denture can achieve the restoration effect of less invasion, better adhesion, aesthetics, comfort and good biocompatibility. With high patient satisfaction, it can be considered an ideal restoration method for replacing a single anterior tooth.

10.
Heliyon ; 9(12): e23046, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38076041

RESUMO

Statement of problem: The relation between cement color and abutment substrate material and the corresponding effect on the color accuracy of high-transparency pre-colored zirconia (HT-Zr) remains unclear. Purpose: This in-vitro study aimed to investigate the difference in color accuracy when the HT-Zr is bonded to different materials-based substrates with differently colored resin cement. Materials and methods: Vita A1 shade HT-Zr with 1 mm thickness was used as the testing sample. The samples were first placed on zirconia (ZR), tooth color resin (CR), and metallic (MT) abutment substrates. Subsequently, four differently colored cements (translucent (TR), bleach, opaque, and A2 shade (A2)) were used for bonding HT-Zr onto the substrate, and the non-bonded group was used as the control group (CG). There were 15 groups in total (n = 10 per group). A digital colorimeter was used to obtain Commission Internationale de l'Eclairage (CIELab) color parameters. The translucency parameter (TP00) of the substrate and sample, as well as color difference (ΔE00) and chroma (C) between the different groups were calculated. Additionally, the ΔE00 and TP00 were compared with the moderately unacceptable match of ΔE00 = 3.6. The statistical analysis was conducted using ANOVA and Tukey HSD post-hoc test (α = 0.05). Results: HT-Zr exhibited high translucency (TP00 = 11.02 ± 0.18), and the mean ΔE00 of the testing samples ranged between 2.18 ± 0.20 and 13.14 ± 0.31. The ZR-CG and MT-A2 groups showed the highest and lowest lightness separately. The CR-CG group exhibited the highest C, and the ΔE00 was lower than that of 3.6. The MT-TR group showed the lowest C and the highest ΔE00. The inter-group comparison revealed that the ΔE00 for different cement is mostly lower than the acceptable color match of 1.0; moreover, the ΔE00 for all the substrates, excluding the CG group, is higher than 3.6. Conclusions: The abutment substrate materials and the cement color should be considered with caution when using HT-Zr, with the effect of abutment substrate materials being more apparent in color accuracy. HT-Zr restorations are not recommended for discolored or bleached abutments but only for natural-colored abutments to achieve the optimal color appearance.

11.
Front Bioeng Biotechnol ; 11: 1259707, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107620

RESUMO

Objectives: This study aimed to investigate whether the atmospheric pressure plasma jet (APPJ) could modify the surface of lithium disilicate glass ceramics (LDC) instead of hydrofluoric acid (HF) in LDC resin cementation. Methods: Two hundred and thirty-two LDC blocks were randomly divided into seven groups: Group 1 (16 specimens) was the blank control group (without HF or APPJ treatment); Group 2 (36 specimens) was etched by HF; Groups 3-7 (36 specimens each) were treated with APPJ, and the relative air humidity (RAH) of the discharge was 22.8%, 43.6%, 59.4%, 75.2%, and 94.0%, respectively. Three LDC blocks in each group were characterized via X-ray photoemission spectroscopy (XPS) analyses, 3 blocks via contact angle measurements, and other 10 blocks via surface roughness measurements. The residual LDC blocks in groups 2-7 were cemented to composite cylinders. Testing the cemented specimens' shear bond strength (SBS) before and after thermocycling (6,500 cycles of 5°C and 55°C) revealed fracture patterns. Data were analyzed by ANOVA (post hoc: Bonferroni) (α = 0.05). Results: After APPJ treatment, the water contact angle values of APPJ treated blocks dropped from 31.37° to 5.66°, while that of HF etched ones dropped to 18.33°. The O/C ratio increased after HF etching or APPJ treatment according to the calculated results, except for the APPJ-treated samples at a RAH of 22.8%. The surface roughness of LDC blocks showed no statistic difference before and after APPJ treatment, but experienced significant difference after HF etching. The O/Si and O/C ratios varied after HF etching or APPJ treatment. No significant difference in SBS values could be found among groups 2-7 before or after artificial aging (p > 0.05). All specimens showed mixed failure patterns. Conclusion: The APPJ treatment method reported in this study is a promising novel strategy for surface modification of the LDC. With acceptable bonding strength, it might be an alternative to HF in LDC-resin cementation.

12.
J Contemp Dent Pract ; 24(10): 725-728, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152902

RESUMO

AIM: The purpose of this study was to evaluate the bond strength and fracture mode of universal resin cement to dentin compared to self-adhesive and adhesive resin cement with and without an adhesive bonding agent. MATERIALS AND METHODS: Seventy-two molar teeth were sectioned to expose coronal dentin, divided into three groups, and assigned to RelyX Universal (universal), RelyX Ultimate (adhesive), or RelyX Unicem 2 (self-adhesive) cements from 3M. The 3 groups were further subdivided into 2 subgroups of 12 specimens each, with or without the use of an adhesive bonding agent. Lithium-disilicate discs were bonded to the dentin surface using the cements, stored for 24 hours in distilled water, and subjected to 2,000 thermocycles before shear bond strength testing and fracture mode analysis. RESULTS: Significant differences in bond strength and fracture mode were found between groups based on cement or the use of a bonding agent. Both the universal and adhesive cements had significantly greater bond strengths to dentin with the use of a bonding agent versus no bonding agent. With the self-adhesive cement, there was no significant increase in bond strength to dentin with the use of a bonding agent. CONCLUSION: The novel universal resin cement had similar bond strengths to dentin as the adhesive cement with the use of a bonding agent, and similar bond strengths as the self-adhesive cement without the use of a bonding agent. The adhesively bonded universal cement had the greatest percentage of mixed and cohesive fractures. CLINICAL SIGNIFICANCE: When greater adhesion is needed clinically, the novel universal resin cement may be used with an adhesive bonding agent. However, when less adhesion is needed, it could be used without a bonding agent in self-adhesive mode.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários/química , Cimentos de Ionômeros de Vidro/química , Dentina , Teste de Materiais , Análise do Estresse Dentário , Adesivos Dentinários/química , Propriedades de Superfície , Resistência ao Cisalhamento
13.
Clin Oral Investig ; 27(12): 7833-7840, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37989965

RESUMO

OBJECTIVES: To assess the effect of glass-ceramic coated zirconia versus alumina air-abraded zirconia on the shear bond strength (SBS) of resin cement and investigate the residual stresses present on both mechanically pre-treated surfaces. MATERIALS AND METHODS: A total of 180 zirconia disks, with diameters of 10 mm and 5 mm, were divided into two groups: DCMhotbond glass-ceramic coated, followed by hydrofluoric acid etching (DCM), and alumina air-abraded (AB). All mechanically pre-treated disks were conditioned with G-Multi Primer and bonded using G-Cem Linkforce Cement. Ninety specimens were immersed in distilled water for 24 h and subsequently allocated into three groups based on aging conditions (n = 15/subgroups): immediate testing, 5000 thermal cycles, and 10,000 thermal cycles. Then, the shear bond strength was assessed, and the obtained data were subjected to analysis using a two-way ANOVA, followed by a one-way ANOVA and Tukey's HSD post hoc test (α = 0.05). The residual stresses present on both mechanically pre-treated surfaces were examined using X-ray diffraction analysis. RESULTS: The mean SBS values of the DCM and AB groups showed no significant difference under each aging condition. The SBS of DCM groups was not affected by thermal cycles, whereas the SBS of AB groups exhibited a significant decrease following thermal cycles. Glass-ceramic coated surfaces exhibited higher compressive stresses than alumina air-abrasion. CONCLUSIONS: The DCMhotbond glass-ceramic coated zirconia showed comparable bond strength to the alumina air-abrasion technique. CLINICAL RELEVANCE: The DCMhotbond glass-ceramic coating technique is a promising alternative for zirconia surface pre-treatment. However, further investigations are needed before suggesting its clinical use.


Assuntos
Colagem Dentária , Óxido de Alumínio/química , Propriedades de Superfície , Cerâmica/química , Cimentos de Resina/química , Zircônio/química , Resistência ao Cisalhamento , Teste de Materiais , Análise do Estresse Dentário
14.
PeerJ ; 11: e16469, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38025677

RESUMO

Background: This study aimed to evaluate the load capacity of maxillary central incisors with simulated flared root canal restored with different fiber-reinforced composite (FRC) post cemented with either self-adhesive or self-etch resin cement and its mode of fracture. Methods: Sixty-five extracted maxillary incisors were decoronated, its canal was artificially flared and randomly categorized into group tFRC (tapered FRC post) (n = 22), mFRC (multi-FRC post) (n = 21), and DIS-FRC (direct individually shaped-FRC (DIS-FRC) post) (n = 22), which were further subdivided based on cementation resin. The posts were cemented and a standardized resin core was constructed. After thermocycling, the samples were loaded statically and the maximum load was recorded. Results: The load capacity of the maxillary central incisor was influenced by the different FRC post system and not the resin cement (p = 0.289), and no significant interaction was found between them. Group mFRC (522.9N) yielded a significantly higher load capacity compared to DIS-FRC (421.1N). Overall, a 55% favorable fracture pattern was observed, and this was not statistically significant. Conclusion: Within the limitation of the study, it can be concluded that prefabricated FRC posts outperform DIS-FRC posts in terms of the load capacity of a maxillary central incisor with a simulated flared root canal. The cementation methods whether a self-adhesive or self-etch resin cement, was not demonstrated to influence the load capacity of a maxillary central incisor with a flared root canal. There were no significant differences between the favorable and non-favorable fracture when FRC post systems were used to restored a maxillary central incisor with a flared root canal.


Assuntos
Fraturas Ósseas , Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Incisivo/cirurgia , Cimentos de Resina/uso terapêutico , Cimentação/métodos , Cavidade Pulpar/cirurgia , Resinas Compostas/uso terapêutico , Estresse Mecânico , Resinas Vegetais
15.
Saudi Dent J ; 35(6): 734-740, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37817783

RESUMO

Objective: The aim of this study was to evaluate the effect of thermocycling on shear bond strength (SBS) of several resin cement materials to different types of zirconia dental ceramics. Materials and Methods: 120 square shaped disc specimens were fabricated using two types of zirconia blocks (Sagemax and Sirona). Each zirconia group was divided into three sub-groups based on the resin cement bonded to the specimens. Three different self-adhesive resin cements were used (Calibra, Breeze and RelyX). The specimens were further grouped into experimental and control groups (n = 10). The experimental specimens were exposed to a thermo-cycling protocol of 1500 cycles in water bath at 5c and 55c. Specimens were then stored at 37c for 24 h then all specimens underwent SBS test with an Instron machine. Mode of failure was inspected visually and microscopically. Data were statistically analyzed using multivariate analysis of variance followed by one-way analysis of variance, Tukey's multiple comparison test, student's t-test for independent samples were used to compare the mean values of SBS in relation to the categorical study variables. Results: The mean SBS values of experimental groups were significantly lower than control groups for all the 6 combinations of Zirconia and cement types (p < 0.0001). The higher mean difference (14.29 MPa) was observed in the combination of Sagemax and Rely-X. Rely-X displayed the highest SBS among all the cements while no significant difference was found in mean SBS values of Calibra and Breez cements in all groups. The mean SBS values of Sagemax zirconia were significantly higher than the Sirona with all three types of cements (p < 0.0001) within control groups. Microscopic and visual analysis demonstrated a majority of adhesive mode of failure. Conclusion: Thermocycling significantly reduced the SBS between the zirconia materials and self-adhesive resin cements tested. The amount of reduction varies according to cement and zirconia types.

16.
Aust Dent J ; 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37888911

RESUMO

BACKGROUND: Medium-term evaluate the bond strength and tag formation in root dentin using self-adhesive cements Maxcem Elite (MCE), Relyx U200 (RU2), SeT PP (SPP) and Megalink (MGL) compared to conventional cement Relyx ARC (ARC) for glass fibre post cementation. MATERIALS AND METHODS: One hundred bovine incisors roots were endodontically treated and divided into 5 groups (n = 20) according to the cementation system: MCE, RU2, SPP, MGL and ARC. All cementation systems were evaluated at 24 h (1) and 12 months (2) after post cementation. Specimens from the cervical, middle and apical thirds of the root were submitted to push-out bond strength test and confocal laser microscopy to verify the dentin penetration. The adhesive failure mode was classified as adhesive, cohesive and mixed. Data were analysed by one-way ANOVA and Tukey tests (α = 5%). RESULTS: ARC-1 and ARC-12 showed the highest bond strength (P < 0.05). ARC showed the greatest tag extension, regardless of the third (P < 0.05). The most frequent failure mode in the 24-h analysis was cohesive, regardless of the cement used. For the 12-month analysis, mixed failure was the most frequent. CONCLUSION: Conventional cement (ARC) showed the highest bond strength and tag extension, regardless of the evaluation period. In all cementation systems, the bond strength decreased after 12 months. © 2023 Australian Dental Association.

17.
Medicina (Kaunas) ; 59(10)2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37893515

RESUMO

Background and Objectives: Although fiber posts are widely used in the restoration of endodontically treated teeth (ETT), their ideal cementation depth into the root canal is still debated in literature. The aim of the present study was to evaluate whether the different intra-radicular insertion lengths of the fiber posts influence the fracture strength of ETT. Materials and Methods: A total of 10 permanent human lower incisors with straight roots of similar length and volume extracted for periodontal reason were sectioned 2 mm above the cement-enamel junction (CEJ) to a total length of 18 mm and endodontically treated in the same manner, then randomly divided into two groups of five each (Groups 1 and 2, n = 5). Two sound incisors, with no endodontic treatment, were used as the control group (Group 3, n = 2). After one week of storage in a humid environment, spaces for fiber post no. 1 (Reforpost, Angelus, Londrina, PR, Brazil) were prepared in the first two groups at a depth of 5 mm (Group 1) and 7 mm (Group 2), and the fiber posts were adhesively cemented using self-adhesive resin cement (Maxcem Elite, Kerr GmbH, Herzogenrath, Germany). After 7 days, the samples were vertically positioned and fixed in a self-curing transparent acrylic resin, up to 2 mm below the CEJ level, and mechanically tested in compression after another week of storage using a displacement-controlled testing machine up to each sample's fracture. The force-displacement curves were recorded for each sample, the means were calculated for each group and a statistical comparative analysis between groups was conducted. Results: Although no statistically significant differences between groups were observed, the highest mean fracture force (N) was recorded in Group 2 (1099.41 ± 481.89) in comparison to Group 1 (985.09 ± 330.28), even when compared to the sound, non-treated teeth (1045.69 ± 146.19). Conclusions: Within the limitations of this in vitro study, teeth where fiber posts were placed deeper into the root canal (7 mm) recorded slightly higher fracture forces in comparison with shorter lengths (5 mm). However, similar biomechanical performances obtained in the mechanical tests showed no statistical differences between the 7 mm and the 5 mm inserted posts.


Assuntos
Fraturas dos Dentes , Dente não Vital , Humanos , Resistência à Flexão , Resinas Compostas , Dente não Vital/terapia , Incisivo
18.
Dent Mater J ; 42(6): 806-817, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37880134

RESUMO

The aim was to develop dual-cured resin cements containing Sr-bioactive glass nanoparticles (Sr-BGNPs; 5 or 10 wt%) and monocalcium phosphate monohydrate (MCPM; 3 or 6 wt%). Effects of additives on degree of monomer conversion (DC), biaxial flexural strength/modulus, shear bond strength (SBS), mass/volume change, color stability, ion release, and cytotoxicity were examined. Controls included material without reactive fillers and Panavia SA Plus (PV). Experimental cements showed higher DC than PV regardless of light activation (p<0.05). Mean SBS and color stability were comparable between experimental cements and PV. Cell viability upon the exposure to sample extracts of experimental cements was 80%-92%. High additive concentrations led to lower strength and modulus than PV (p<0.05). The additives increased mass change, reduced color stability, and promoted ion release. The experimental resin cements demonstrated acceptable mechanical/chemical properties and cytotoxicity. The additives reduced the strength but provided ion release, a desirable action to prevent recurrent caries.


Assuntos
Resistência à Flexão , Cimentos de Resina , Cimentos de Resina/toxicidade , Cimentos de Resina/química , Teste de Materiais , Fosfatos de Cálcio/toxicidade
19.
Artigo em Inglês | MEDLINE | ID: mdl-37814894

RESUMO

INTRODUCTION: The degree of conversion (DC) of resin cements can be affected by ceramics, and by the type of resin cement. The purpose was to evaluate the influence of thickness and translucencies of lithium disilicate ceramic on the DC of resin cements: two light-cure (Variolink LC; NX3 LC) and one dual-cure (NX3 Dual). METHODS: IPS e.max Press ceramic (A2) discs were prepared in 4 thicknesses (0.3, 0.5, 1.0, and 1.5 mm) and in 3 translucencies: HT (high translucency), LT (low translucency), and MO (medium opacity). Subsequently, 234 samples of resin cement (5 x 1 mm) were light-cured through those ceramic discs. The DC was assessed by Fourier Transform Infrared Spectroscopy (FTIR). RESULTS: Ceramic thicknesses decreased DC of NX3 Dual through HT-1.0 and HT 1.5 (p=0.005). Between translucencies, only MO-0.3 affected Variolink LC DC (p=0.018). There was difference among light- and dual-cured resin cements (p=0.001). CONCLUSION: Increasing thickness and opacity lead to a decrease in the DC of all resin cements, with a significantly lower DC value in NX3 Dual (HT-1.0; HT-1.5), and in Variolink LC (MO- 0.3). Light- and dual-cured resin cements were different among each other. NX3 Dual achieved a significantly lower value than its counterpart NX3 LC.

20.
Cureus ; 15(9): e45045, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37829958

RESUMO

This systematic review and meta-analysis aimed to evaluate the effect of different surface treatments on the shear bond strength (SBS) values between zirconia and resin cement compared to untreated specimens. The effects of various surface treatments on the bond strength between zirconia and resin cement were investigated by searching relevant articles on PubMed, ScienceDirect, and Google Scholar databases. A total of 13 studies that met the inclusion and exclusion criteria and addressed the research question were selected for statistical analysis. The studies were evaluated for heterogeneity, and a meta-analysis was performed. In total, 13 in vitro studies were included in accordance with the eligibility criteria. All 13 studies consistently demonstrated that silica coating yielded the highest SBS, followed by sandblasting and laser treatments. The meta-analysis using a random-effect model indicated a significant intergroup comparison, except for a few studies. Among the three treatments examined, the silica coating of zirconia was identified as the most effective in enhancing the bond strength between zirconia and resin cement. Further controlled laboratory and clinical studies are necessary to validate these findings and explore additional factors that may influence the effects of these surface treatments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...